The block’s mounting screws must not be used as the only means of grounding the block. Connect the green ground screw on the block to a reliable ground system using a short wire lead, minimum size AWG #12(avg 3.3mm2 in cross-section)
Brand: GE Model number:8615-FT-4W
Colour:new Warranty: 1 year
Lead Time:3-day working day Country of origin: USA
Price: Please contact us Product weight:0.12kg
hipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
8615-FT-4W GE Controller module Brand new
CPU sweep time increases during
overtemperature operation
When the operating temperature of the CPU exceeds the normal
operating temperature, system variable #OVR_TMP (%SA8) turns ON
(Fault group 24, error code 0x0001). When this occurs, the sweep time
periodically increases because the CPU executes a new task to read
the actual temperature reported by a temperature sensor. This
increase can be as much as 2 ms.
GBC in expansion rack may fail to power
up
Occasionally, a Series 90-70 GBC module located in an expansion
rack may fail to power up when power to that rack is cycled off/on. The
module’s OK light will flash and then all module lights will go off. Power
cycle the rack again to recover. (Note: This issue does not affect 90-30
GBCs.)
Possible Machine Edition software inability
to connect
Infrequently, an attempt to connect a programmer to an RX7i via
Ethernet will be unsuccessful. The normal connection retry dialog will
not be displayed. Rebooting the computer that is running the
programmer will resolve the behavior.
Don’t use multiple targets In a system in which the hardware configuration is stored from one
target and logic is stored from a different target, powering-up from
flash will not work. The observed behavior is that, following a power up
from flash, Machine Edition software reports hardware configuration
and logic "not equal".
Sequence Store failure When downloading projects with very large hardware configuration or
which use large amounts of user memory, it is possible to encounter a
“PLC Sequence Store Failure” error when writing the project to flash.
To work around this error, either or both of the following actions may
be helpful:
1. Perform an explicit clear of flash prior to performing the write.
2. Increase the operation timeout used by Machine Edition software
prior to performing the write. This is done by expanding the
Additional Configuration in the Inspector window for the target
controller, and adjusting the Request Timeout. The timeout may
need to be increased to as much as 60000 msec, depending on
the amount of memory used and the condition of the flash
memory
GE DS3800DMEC1B1B
GE DS3800DMEC1C1C
GE DS3800DMEC1D1D
GE DS3800DMPC
GE DS3800DMPC1E1C
GE DS3800DMPC1F1E
GE DS3800DMPK1B1B
GE DS3800DMPK1E1D
GE DS3800DOAA
GE DS3800DPLA1B1A
GE DS3800DPSS1B1B
GE DS3800DPSS1C1C
GE DS3800DPZA1D1D
GE DS3800DSHA1A1A
GE DS3800DSHA1A1B
GE DS3800DSQD1A1A
GE DS3800DSWA
GE DS3800DXRA
GE DS3800DXRA1C1C
GE DS3800DXRC
GE DS3800DXRC1
GE DS3800HACA
GE DS3800HACA1A1A
GE DS3800HACB
GE DS3800HADA
GE DS3800HADA1A1A
GE DS3800HADA1B1B
GE DS3800HAFA1B1D
GE DS3800HAFA-1D1E
GE DS3800HAIA1D1B
GE DS3800HAIA1E1D
GE DS3800HAIA1EID
GE DS3800HAIC1A1A
GE DS3800HAIC1A1A 6BA00C
GE DS3800HAIC1A1A6BA00C
GE DS3800HAIC1E1C
GE DS3800HARA1B1C
GE DS3800HCIB
GE DS3800HCIB1B
GE DS3800HCIB1B1C
GE DS3800HCID
GE DS3800HCM1A1B
GE DS3800HCMA1E1G
GE DS3800HCMB
GE DS3800HCMB1C1C
GE DS3800HCMC
GE DS3800HCMC1A1B
GE DS3800HCMC-1A1B
GE DS3800HCVA1H1G
GE DS3800HCVA1J1G
GE DS3800HDDD
GE DS3800HDID1A1A
GE DS3800HDRA
GE DS3800HDRA1B
GE DS3800HDRA1B1B
GE DS3800HDRC1A1A
GE DS3800HFPB1F1E
GE DS3800HFPC
GE DS3800HFPC1L1H
GE DS3800HFPE1D1C
GE DS3800HFPG1C1B
GE DS3800HFPG1D1B
GE DS3800HFPG1D1C
GE DS3800HFPG1D1D
GE DS3800HFPG1E1E
GE DS3800HFXA1F1D
GE DS3800HFXB
GE DS3800HFXB1G1C
GE DS3800HFXB1R1H
GE DS3800HFXC
GE DS3800HFXD
You are welcome to make an inquiry
E-mail:
free@fenoux.com
Tel.:
+86 133 7698 4225
Skype:
+86 133 7698 4225
WhatsApp:
+86 133 7698 4225